MIL-DTL-81963C
TABLE II. Endurance test time schedule.
Specification number
Shaft
MIL-S-22432
position
MIL-S-22820
SAE-AS20708
MIL-T-22821
Temperature
Temperature
Time 1/
Time 1/
(Hours)
°C
(Hours)
°C
64 ± 2
-55 ± 5
64 ± 2
-55 ± 5
Horizontal
H 2/
H 2/
24 ± 2
24 ± 2
Vertically Upward
H 2/
H 2/
24 ± 2
24 ± 2
45° Upward
H 2/
H 2/
24 ± 2
24 ± 2
45° Downward
H 2/
H 2/
24 ± 2
24 ± 2
Vertically downward
15° to 30°
15° to 30°
740 ± 4
1840 ± 4
Horizontal
(see 4.2.1)
(see 4.2.1)
100 ± 3
3/ 100 ± 5°
Horizontal
1/ Fifty (50) percent of rotation to be CW and 50 percent of rotation to be CCW.
2/ H is the ambient temperature specified in the applicable general specification.
3/ For MIL-S-22432 and MIL-S-22820, the 100 hours at 100 degrees C portion of the test shall be
performed at maximum power output, as specified in MIL-S-22432 and MIL-S-22820.
TABLE III. Zero defect sampling plan.
Sample size
Sample size
Lot size
For group A
For group B
1
to
2
100 percent
100 percent
3
to
12
100 percent
3
13
to
50
13
5
51
to
90
13
7
91
to
150
13
11
151
to
280
20
13
281
to
500
29
16
501
to 1,200
34
19
1,201
to 3,200
42
23
3,201
to 10,000
50
29
26
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business